Multi-Parameter Monitor Model CSI-300

$799.00

Out of Stock! Due to the Coronavirus, some of the following devices are unavailable at this time. Others are in the process of manufacturer following FDA Approval. For either of these situations, you may place your order with the understanding that no charges will be processed against your credit card until such time as the goods are available to be shipped.

Description

The Multi-Parameter Spot-Check Monitor is a device designed for measuring the user’s physiological parameters, such as non-invasive blood pressure (NIBP), oxygen saturation (SpO2), pulse rate (PR), and body temperature (TEMP). The ISYC version can also be used for the measurement of Blood Glucose and ECG. This device is applicable for use in clinical institutions and the home.

Additional information

Weight 1.81437 kg
Dimensions 27.94 × 27.94 × 27.94 cm
Model

CSI-300

Features

1) Small in size, light in weight, easy to carry and operate
2) Clear and large numeric display by segment LCD panel with real-time clock
3) Accurate blood pressure measurement
4) Unique oximetry technique ensures quick and accurate SpO2 & Pulse measurement
5) Smart infrared temperature probe ensures quick and accurate measurement of TEMP
6) Blood pressure, oxygen saturation, pulse and temperature can be measured simultaneously
7) Blood Glucose meter can be connected for measurement, display and collection of data
8) Data storage with recall up to 999 groups of data records
9) Power measurement with power saving mode, auto power off and low battery indication
10) Data upload or transfer by either USB or wirelessly using Bluetooth 4.0

Specifications

1) Blood Pressure Measurement
1.1) Technique: Sociometric
1.2) Pressure measuring range: 0 mm/Hg~300 mm/Hg
1.3) Cuff inflation time:<20 seconds (typical adult cuff)
1.4) Accuracy of pressure measurement: ±3 mm/Hg
1.5) Overpressure protection limit
1.6) Adult: 300 mm/Hg(39.9 kPa)
1.7) Blood pressure measuring range: SYS: 60mm/Hg~240mm/Hg DIA: 30mm/Hg~180mm/Hg
1.8) Blood pressure measuring accuracy: Maximal mean difference: ±5 mm/Hg
1.9) Maximal standard deviation: 8 mm/Hg
2) SpO2 Measurement
2.1) Technique: optical with dual-wavelength: LED wavelength: Red light: 663 nm, Infrared light: 890 nm
2.2) SpO2 measuring range: 35%~100%
2.3) SpO2 measuring accuracy: Arms is not greater than 3% for SpO2 range from 70% to 100%
Note: Arms is defined as root-mean-square value of deviation according to ISO 9919
2.4) Low perfusion performance: the above declaration is still attained while the amplitude modulation ratio is as low as 0.6%.
3) Pulse Rate Measurement
3.1) PR measuring range: 30 bpm~240 bpm
3.2) Pulse rate measuring accuracy: ±2 bpm or ±2%, which is greater
4) Temperature Measurement
4.1) Measuring range: 32.0°C~43.0°C
4.2) Measuring accuracy: ±0.2°C is for TEMP range from 35.0°C to 42.0°C, and ±0.3°C is for the rest.
4.3) Response time: <5 sec.
5) Blood Glucose Measurement (Optional)
5.1) Technique: Amperometric, glucose oxidase
5.2) Measuring range: 1.1 mmol/L ~ 33.3 mmol/L (20~600 mg/dL)
5.3) Measuring time: 6 seconds
6) ECG Measurement
6.1) Heart Rate measuring range: 30 bpm~240 bpm
6.2) Heart Rate measuring accuracy: ±2 bpm or ±2% whichever is greater
6.3) Display scale: 5.0 mm/mV ±10%
6.4) Common-mode rejection ratio (CMRR): 60 dB
7) Operating Environment
7.1) Operating temperature: 5°~ 40°; Relative humidity:15% ~ 93%;
7.2) Atmospheric pressure: 70.0 kPa ~106.0 kPa; Power supply: A.C. 110V-240V AC, 50/60 Hz;
7.3) Internal power supply: DC 3.7V (rechargeable Lithium battery); Input: 15VA
7.4) The device should be situated in a place protected against direct sunlight, so as to prevent overheating